# nano -w /etc/apt/sources.list.d/mcp.list
+ deb http://downloads.linux.hpe.com/SDR/repo/mcp xenial/current non-free
# curl http://downloads.linux.hpe.com/SDR/hpPublicKey1024.pub | apt-key add -
# curl http://downloads.linux.hpe.com/SDR/hpPublicKey2048.pub | apt-key add -
# curl http://downloads.linux.hpe.com/SDR/hpPublicKey2048_key1.pub | apt-key add -
# curl http://downloads.linux.hpe.com/SDR/hpePublicKey2048_key1.pub | apt-key add -
# apt-get update
# /sbin/hplog -t -f -p
ID TYPE LOCATION STATUS CURRENT THRESHOLD
1 Basic Sensor I/O Zone Normal 102F/ 39C 158F/ 70C
2 Basic Sensor Ambient Normal 62F/ 17C 102F/ 39C
3 Basic Sensor Processor Zone Normal 86F/ 30C 260F/127C
4 Basic Sensor Processor Zone Normal 86F/ 30C 260F/127C
5 Basic Sensor System Board Normal 105F/ 41C 170F/ 77C
6 Basic Sensor Processor Zone Normal 86F/ 30C 260F/127C
7 Basic Sensor Processor Zone Normal 86F/ 30C 260F/127C
ID TYPE LOCATION STATUS REDUNDANT FAN SPEED
1 Var. Speed I/O Zone Normal Yes Normal ( 45)
2 Var. Speed I/O Zone Normal Yes Normal ( 45)
3 Var. Speed I/O Zone Normal Yes Normal ( 45)
4 Var. Speed I/O Zone Normal Yes Normal ( 45)
5 Var. Speed Processor Zone Normal Yes Normal ( 41)
6 Var. Speed Processor Zone Normal Yes Normal ( 41)
7 Var. Speed Processor Zone Normal Yes Normal ( 36)
8 Var. Speed Processor Zone Normal Yes Normal ( 36)
9 Var. Speed Processor Zone Normal Yes Normal ( 36)
10 Var. Speed Processor Zone Normal Yes Normal ( 36)
11 Var. Speed Processor Zone Normal Yes Normal ( 36)
12 Var. Speed Processor Zone Normal Yes Normal ( 36)
ID TYPE LOCATION STATUS REDUNDANT
1 Standard Pwr. Supply Bay Normal Yes
2 Standard Pwr. Supply Bay Normal Yes
# /usr/sbin/hpssacli ctrl slot=1 show config
Smart Array P400 in Slot 1 (sn: **************)
Port Name: 1I
Port Name: 2I
Internal Drive Cage at Port 1I, Box 1, OK
Internal Drive Cage at Port 2I, Box 1, OK
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (136.7 GB, RAID 1, OK)
physicaldrive 2I:1:1 (port 2I:box 1:bay 1, SAS, 146 GB, OK)
physicaldrive 2I:1:2 (port 2I:box 1:bay 2, SAS, 146 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 146 GB, OK, spare)
array B (SAS, Unused Space: 0 MB)
logicaldrive 3 (136.7 GB, RAID 1, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 146 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 146 GB, OK)
physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 146 GB, OK, spare)
#!/bin/bash
#===== HP log
FILELOG1="/root/log/"$(date +%Y%m%d%H%M%S)_log.txt
touch $FILELOG1
/sbin/hplog -t -f -p &>$FILELOG1
#=====
#===== HP array
FILELOG2="/root/log/"$(date +%Y%m%d%H%M%S)_arr.txt
touch $FILELOG2
/usr/sbin/hpssacli ctrl slot=1 show config &>$FILELOG2
#=====
sendemail -f kvm@myDomain -t giancarlo.birello@myDomain -u Status -m Status -a $FILELOG1 $FILELOG2 -s mail.myDomain -q